Janoshik tested this Heiotropin sample at 92.158% purity. The tested quantity of 7.65 IU was significantly below the 10 IU label, representing a -23.5% deviation. There is no information on the test method or endotoxin status. The test is older (6-12 months), but customers can cross-check on the lab's public verification URL.
- significant quantity deviation
- no endotoxin test
- older (6-12 months)
Test report image
Janoshik (public)
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Dose
- 10iu
- Catalogued
- 2026-04-22
- Artifact hash
a31467dbe4350b60…
OCR text
Raw extracted text
Raw extracted text
Extracted via OCR. Names, emails, phone numbers, and street addresses are auto-redacted before display.
{"peptide": "Heiotropin", "dose": "10iu", "purity_pct": 92.158, "purity_label": "92.158%", "method": "", "test_date": "2025-10-08", "client": "ADVARPHARMA DK", "notes": "", "label_qty": "10iu", "tested_qty": "7.65 IU", "quantity_deviation_pct": -23.5, "is_blend": false, "components_json": "", "ocr_confidence": 0.92}