This COA was tested by an independent third-party lab, LabF. The retatrutide batch SART1520250718F showed 99.69% purity via HPLC, with mass quantification also performed. The tested quantity of 16.77mg significantly exceeded the 15mg label by 11.8%. Endotoxin status is not applicable, and the test recency is unknown. Customers can verify this COA via the lab's public URL.
- unknown test date
- no endotoxin test
- quantity deviation (11.8%)
Test report image
Finnrick
✓ Artifact capturedWe have the certificate image (SHA-256 hash captured) — you can verify it loads from the upstream lab and matches the artifact below.
Verify on upstream- Method
- HPLC + mass quantification + endotoxins
- Test type
- finnrick_composite
- Dose
- 15mg
- Container
- No Label / Silver Crimp / Blue Cap
- Catalogued
- 2026-04-16
- Artifact hash
75ea70833212ace9…